Kidde Airsense–Aspiring Smoke Detection

High Sensitivity Smoke Detection system (HSSD)

HSSD systems are an early warning of an incipient fire condition and therefore a precursor to and of higher sensitivity than a conventional smoke detector, therefore NOT required at that stage of sensitivity to be linked to the main building fire alarm system.

  • Avoids probable escalation to a gas release
  • It can avoid possible shutdown of air con controlling the Server Room with possible overheat and loss of Server function.
HSSD

Stratos HSSD 2 (Aspirational Panel)

Stratos HSSD 2 is designed to provide very high sensitivity smoke detection for large areas.

ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the detector will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.

Volt-free contacts ensure compatibility with any fire alarm system. Each detector is provided with 3 monitored inputs. The inputs may be configured for a number of functions, see technical documentation for full details.

Stratos HSSD 2

HSSD (Aspirational Panel)

Stratos-Micra 25 is designed to provide very high sensitivity smoke detection in an ultra small package.

ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.

The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation.

Volt-free contacts ensure compatibility with any fire alarm system.

HSSD (Aspirational Panel)

HSSD (Aspirational Panel)

Stratos-Micra 100 is designed to provide very high sensitivity smoke detection in a small package.

ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.

The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation.

Volt-free contacts ensure compatibility with any fire alarm system.

HSSD (Aspirational Panel)

ELSA CONTROL PANEL

3L-NDP – Locating Panel

FEATURES & BENEFITS:
  • Maximum accumulated length of sensing cable : 10m
  • Maximum accumulated length of jumper cable : 300m
  • Failsafe Operation : Ability to operate in loop installation Ability to detect/locate liquid leakage during cable break.
  • Time to detect Leak/Cablebreak : 3 seconds typical.
  • Liquid leak detection data : Typically 20mm in length of liquid (such as tap water) in full contact with sensing cable, leak sensitivity is adjustable.
  • Multi-leak detection and location capability.
  • Remote supervision by RS-485 Modbus.
  • ASIC-based digital location principle (patent pending) with inherent temperature stability, zero-drift and very low power consumption.
ELSA 3L- NDP

ELSA CONTROL PANEL

3L-NP – Non-Locating Module

FEATURES & BENEFITS:
  • S1+S2+…+Sn <=6 0m
  • J1+ J2+…+ Jn <=1 00m
  • Sensitivity can be adjusted manually.
  • 1x Dry contact relay output for leak or cable-break
  • Typical Application
  • To monitor small room area (typically 20sqm)
  • where leak can be located easily such as Pantry room, drip trays.
ELSA 3L- 3LNP

Sensing Cable 3L-LS

FEATURES & BENEFITS:
  • Application: Water and slightly-corrosive conductive liquids.
  • Diameter size: 6mm average.
  • Continuity wires: White & Red insulated with flame-retardant polymer.
  • Sensing wires: 2 x Black wires, semi-conductive polymer.
  • Carrier: Flame-retardant polymer material with greenish color in high visibility.
  • Fire resistance: Non-flame propagating and self-extinguishing.
Sensing Cable ELSA 3LLS

Sensing Cable 3L-AS

FEATURES & BENEFITS:
  • Application: Highly-corrosive conductive liquids such as 100% Sulfuric Acid.
  • Diameter size: 6mm average.
  • Continuity wires: White & Red insulated with fire-resistant fluoropolymer.
  • Sensing wires: 2 x Black wires, semi-conductive fire-resistant fluoropolymer.
  • Carrier: Fire-resistant fluoropolymer material with yellowish color in high visibility.
  • Fire resistance: UL910 (NFPA 262), highest Fire/Smoke standard.
Sensing Cable 3L-AS
Dealer Enquiry?

We're always looking for opportunities to expand our worldwide dealer network! Please complete the form below if you're interested in selling our products.

Thank You, form was submitted